Refine Your Search

Topic

Search Results

Standard

Measurement of Exterior Sound Level of Specialized Aircraft Ground Support Equipment

2006-10-13
HISTORICAL
ARP1801
The scope of this recommended practice covers specialized internal combustion engine powered equipment used in the support of aircraft operations. The equipment may be self-propelled, truck mounted, trailer mounted, skid mounted or stationary. It does not include construction equipment or equipment designed primarily for operation on highways or within factories or building areas.
Standard

TRANSMISSION INTERLOCKS

1996-05-01
HISTORICAL
AIR1361
The following recommendations and suggestions are made for consideration for procurement of new equipment, or modification to existing equipment where practical. Excluded from this AIR is mobile ground equipment, such as fork lift trucks and front end loaders, that have a functional requirement for simultaneous vehicle motion and accessory operation.
Standard

Transmission Interlocks

2012-07-31
CURRENT
AIR1361A
The following recommendations and suggestions are made for consideration for procurement of new equipment, or modification to existing equipment where practical. Excluded from this AIR is mobile ground equipment, such as fork lift trucks and front end loaders, that have a functional requirement for simultaneous vehicle motion and accessory operation.
Standard

Method of Evaluating Pneumatic Ground Power Units

2003-11-21
HISTORICAL
AIR4545
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

Method of Evaluating Pneumatic Ground Power Units

2020-09-23
CURRENT
AIR4545A
This SAE Aerospace Information Report (AIR) covers, and is restricted to, the behavior of air under conditions of critical and subcritical flow at temperatures less than 500 °F.
Standard

Fuels in Ground Support Equipment (Other Than Gasoline or Diesel)

1999-01-01
HISTORICAL
AIR5373
This SAE Aerospace Information Report (AIR) is intended as a source of comparative information and is subject to change to keep pace with experience and technical advances. This document describes currently used fuels and fuels which may be used in the future. Conventional gasoline and diesel fuels are intentionally omitted from this document.
Standard

Fuels in Ground Support Equipment (Other Than Gasoline or Diesel)

2020-09-23
CURRENT
AIR5373A
This SAE Aerospace Information Report (AIR) is intended as a source of comparative information and is subject to change to keep pace with experience and technical advances. This document describes currently used fuels and fuels which may be used in the future. Conventional gasoline and diesel fuels are intentionally omitted from this document.
Standard

GROUND ELECTRICAL POWER UNIT BRUSHLESS, SYNCHRONOUS, ELECTRIC MOTOR-DRIVEN 400 HERTZ, 3-PHASE OUTPUT

1985-08-01
HISTORICAL
ARP1480
This recommended practice outlines the general requirements of a continuous duty, electric motor-driven brushless alternator unit for supplying 400 Hz electrical power to high performance commercial transport aircraft. This specification is for a single motor-generator set with one or two outputs. The generator set will generate at the aircraft voltage of 115/200 volts. This unit may be used in a central system of small size or in hangar or electronic shop applications. Power characteristics of this unit at the receptacle will meet MIL-Standard-704 requirements. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

Design Specification for Regional Aircraft Towbarless Tow Vehicle for Pushback and/or Maintenance Towing Operations

2022-03-28
CURRENT
ARP5916A
The tow vehicle should be designed for towbarless push-back and/or maintenance towing of regional type aircraft as specified in 1.3. The design will ensure that the unit will safely secure the aircraft nose landing gear within the coupling system for any operational mode. The purpose of this towing procedure is to achieve a safer and faster operation than is possible with conventional towing equipment.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1991-05-01
HISTORICAL
ARP1148A
This Recommended Practice outlines the electrical performance characteristics for a continuous duty, diesel or gasoline engine driven brushless alternator unit for supplying 400-Hertz electrical power to commercial transport aircraft. It is intended to assist the airlines in standardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations. The combination of the equipment specified herein and the interconnecting cables(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704 requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

GROUND ELECTRICAL POWER UNIT, TRANSPORTABLE 115/200 VOLT AC (NOMINAL) 400 HERTZ, 3-PHASE 4-WIRE (GROUNDED NEUTRAL) Y-CONNECTED SYSTEM

1970-02-01
HISTORICAL
ARP1148
This Recommended Practice outlines the general requirements for a transportable self-contained, continuous duty, diesel engine driven brushless alternator unit for supplying 400-Hertz electrical power to high performance commercial transport aircraft. It is intended to assist the airlines in standardardizing recommendations for various sizes and configurations of equipment and it is a guide for the preparation of detailed specifications by the purchaser. The unit is primarily intended to supply power to the aircraft during passenger loading and unloading, and during servicing operations at airports throughout the world. The combination of the equipment specified herein and the interconnecting cable(s) between the 400-Hertz alternator and the aircraft shall provide power characteristics at the aircraft receptacle which meet MIL-STD-704A requirements for Category "B" equipment. Other limits which are necessary to meet specific conditions must be specified by the purchaser.
Standard

Chassis Mounted Lifts Used to Board Airline Passengers With Mobility Impairments

1999-07-01
HISTORICAL
ARP5141
This SAE Aerospace Recommended Practice (ARP) is intended to recommend a minimum standard, for the design and manufacturer of a self-propelled, chassis mounted passenger boarding vehicle. The vehicle will permit safe operation while minimizing aircraft damage and personnel safety hazards associated with commercial aircraft boarding operations. The vehicle described is intended to be used for assisting wheelchair passengers and passengers with disabilities on and off aircraft with door sill heights of 60 in (152.4 cm) and above.
Standard

Chassis Mounted Lifts Used to Board Airline Passengers With Mobility Impairments

2014-03-11
CURRENT
ARP5141A
This SAE Aerospace Recommended Practice (ARP) is intended to recommend a minimum standard, for the design and manufacturer of a self-propelled, chassis mounted passenger boarding vehicle. The vehicle will permit safe operation while minimizing aircraft damage and personnel safety hazards associated with commercial aircraft boarding operations. The vehicle described is intended to be used for assisting wheelchair passengers and passengers with disabilities on and off aircraft with door sill heights of 60 in (152.4 cm) and above.
Standard

EXHAUST EMISSION LIMITS FOR DIESEL ENGINES USED IN AIRCRAFT GROUND SUPPORT EQUIPMENT AT AIRPORT ENVIRONMENTS

2002-12-16
CURRENT
AIR1312
This Aerospace Information Report (AIR) outlines the conditions which diesel engines should meet when installed and used as prime movers for aircraft ground support equipment at commercial airports. All aircraft ground support equipment with a heavy duty diesel engine as defined on page 24293 of the November 15, 1972 Federal Register and used as a prime mover for the vehicle or equipment should meet all requirements as outlined herein. Typical equipment includes fuel trucks, commissary trucks, baggage tractors, ground power units, air start units, etc.
Standard

Ground Support Equipment Hydraulic Systems, Design and Installation, Recommended Practices for

2022-12-16
CURRENT
ARP4943A
This SAE Aerospace Recommended Practice (ARP) covers the design and installation requirements for hydraulic systems (up to 8000 psig [56 MPa]) for ground support equipment (GSE). This ARP is derived from AS5440, which provides hydraulic system requirements for aircraft. The recommendations herein are primarily intended for GSE that exchange hydraulic fluid with the aircraft, such as hydraulic service carts, rather than GSE with non-interfacing hydraulic systems. The GSE may be mobile, portable, or stationary.
X